Salmson: Chilled Water

EXPANSION SETS Hot water - Chilled water 50 Hz

CHARACTERISTICS

50 Hz

OPERATING LIMITS

Temperature range: +5° à +90°C
Max. ambient temperature: +50°C

APPLICATIONS

• Maintains pressure in closed circuits exposed to temperature variations.
• Absorbs and compensates the expansion and retraction of the network.
• Allows automatic or manual filling of an installation via a tank, isolating the heating or air-conditioning circuit from the town water supply.
For hot water heating circuits (VDI 2035) and chilled-water circuits (up to 40% glycol).
- residential and office buildings;
- hotels, hospitals, clinics;
- shopping centres, shops;
- schools, universities, barracks. • Maintains pressure in closed circuits exposed to temperature variations.
• Absorbs and compensates the expansion and retraction of the network.
• Allows automatic or manual filling of an installation via a tank, isolating the heating
or air-conditioning circuit from the town water supply.
For hot water heating circuits (VDI 2035) and chilled-water circuits (up to 40% glycol).
- residential and office buildings;
- hotels, hospitals, clinics;
- shopping centres, shops;
- schools, universities, barracks.

DESIGN OF THE EXPANSON-H

Pressure maintenance system using pump(s) and an adjustable discharge device.
➤ EXPANSON-H, two-pump version
• Set with:
– two horizontal multi-stage pumps connected to tank by galvanized cast-iron pipe. A standby pump is available.
➤ EXPANSON-H, one-pump version
• Set with:
– one horizontal multi-stage pump connected directly to tank.
• Both versions have:
– an electronic regulation box (CE), with automatic change of pump starting order in two pump version;
– an adjustable discharge device with filter;
– a set of isolating valves and one check valve per pump;
– one set isolating valve (one-pump version);
– one control pressure switch and two safety pressure switches.
The assembly is mounted on a base and connected to a galvanized steel tank (200 to
1,500 litres).

Salmson: Axially Split Case Pump

Axially Split Case Pumps 50 Hz

CHARACTERISTICS

50 Hz

OPERATING LIMITS

Flow up to : 3000 m3/h
Head up to : 250 m

APPLICATIONS

• Municipal water supply
• Irrigation
• District heating & cooling
• Building services
• General industry
• Power stations

ADVANTAGES

• Shaft/bearing configuration designed to ensure up to 50 000 hours working time.
• Split case configuration provides easy access to rotating element without removing bearing housing or disturbing pipework.
• Low NPSH requirement reduces risk of cavitation damage in low suction head condition.
• Rotating parts (Shaft + impeller) are dynamically balanced to minimise vibrations.
• Compact construction models (Through bore arrangement)

Salmson: single in line pumps

SINGLE IN-LINE PUMPS Heating - Air conditioning S.H.W. 50 Hz

CHARACTERISTICS

50 Hz

OPERATING LIMITS

Flow up to: 600 m3/h
Head up to : 70 m

APPLICATIONS

• Heating water circuits according to VDI2035
• Chilled water circuit, glycol water circuit of 20 to 40% glycol and 40 °C
• Cooling water circuits
• Secondary hot water distribution loops
• For all industries where chemically neutral, non-explosive clear liquids without abrasive particles must be pumped.

ADVANTAGES

  • • High hydraulic efficiency
    • Low electrical consumption
    • Direct assembly on pipes (horizontal or vertical) or on concrete base
    • Low sound levels
    • Complete interchangeability between single pumps and twin pumps
    • Almost maintenance free.

Salmson: Single and Twi-Head In-Line Pumps

SINGLE AND TWIN-HEAD IN-LINE PUMPS Heating, Air conditioning, Secondary hot water 50 Hz

CHARACTERISTICS

50 Hz

OPERATING LIMITS

Flow up to: 120 m3/h
Head up to : 31 m

APPLICATIONS

  • • Central heating systems: light commercial and commercial.
    • Air-conditioning.
    • Secondary hot water loop.
    Many industrial or agricultural applications.
    • Greenhouse heating.
    • Pumping of water/glycol mixtures.
    • Circulation of chilled water.

ADVANTAGES

• Thermal overload protection on all motors.
• Direct mounting on horizontal or vertical pipe.
• No coupling: no need for shaft alignment.
• Permanent de-aerating device on mechanical seal.
• Quick and easy installation.
• Practically no maintenance required.
JRL
• Standby pump available at all times.
• Possibility of operating the two pumps in parallel to increase flowrate.
• Pump changeover may be manual or automatic, by MGP control box.

Salmson: Electronically controlled Circulators


ELECTRONICALLY CONTROLLED CIRCULATORS Single and Twin-head Commercial heating 2 poles - 50 Hz Single-phase

CHARACTERISTICS

2 poles - 50 Hz
Single-phase



OPERATING LIMITS

Flow up to : 90 m3/h
Head up to : 11 m

APPLICATIONS

For accelerated water circulation for heating or cooling, with optimization of circulator
operating point.
• Central heating,
• Urban heating,
• Commercial or industrial installations,
• Cooling circuits.
New, old (renovated) installations or extensions.
Circulating pumps recommended for facilities
fitted with thermostatically controlled cocks.
ADVANTAGES
• ENERGY SAVING
- Optimization of the circulator operating point. Energy savings of up to 50% compared to a classic circulating pump.
• ALL-PURPOSE
- These circulating pumps can be adapted to all types of current piping.
• NOISE CONTROL
- They remove the whistle and noise in thermostatically controlled cocks,
- They adapt their speed automatically to the levels of comfort required.
• RELIABILITY
- Their entirely automatic operation does not require either upkeep or purge, - The circulating pumps shutdown by the ON/OFF control, start up for several moments once a day, so as to avoid any blocking due to periods of inactivity. - Electronically operated unit with a non volatile memory for data storage and for the protection of instructions in the event of electricity switch off.
- DXE (fitted with IF units optional):
built-in automatic changeover without exterior equipment.


Salmson: Vertical Booster

BOOSTERS - Range of boosters fitted with MULTi-V or MULTi-H pumps: Commercial and industrial use 2 pole - 50 Hz

CHARACTÉRISTICS

2 poles - 50 Hz

OPERATING LIMITS

Flow rates up to: 195 m3/h
Head up to: 240 m CE

APPLICATIONS

Pressurizing and maintaining pressure of water distribution networks with insufficient
or non existent pressure, in:
- housing, office projects,
- private residences,
- hotels, hospitals, clinics,
- shopping centres, shops,
- schools, high-schools, universities, barracks,
- industrial and farm buildings,
- irrigation, spraying…

ADVANTAGES

  • • Compact modules, factory preset and ready to install.
    • Small ground space.
    • Easy to install: 2 hydraulic connections and one electrical connection.
    • Control and protection functions grouped in the cabinet assuring integral automatic operation.
    • N-ALTi 2/4/8/16 range non-return valve fitted with interchangeable cartridge. Easy to maintain.
    • Stainless steel hydraulic system: reliable corrosion resistance and longer life.
    • Base protected by an electrolytic treatment ensuring excellent resistance to saline mist.

Salmson: Booster

BOOSTERS equipped with 2 horizontal multistage pumps Housing - Small institutions 2 pole - 50 Hz

OPERATING LIMITS

Flow up to: 30 m3/h
Head up to: 65 m

APPLICATIONS

Pressurization and pressure holding in a water distribution network when pressure is
insufficient or non-existent, for suction or on load, used for:
• small housing groups,
• building complexes,
• private residences,
• shops,
• schools.

ADVANTAGES

• Compact ready-to-install sets.
• Small footprint.
• Easy installation: 2 hydraulic connections and 1 electric connection.
• Control and protection grouped together in cabinet to ensure full logic control for operation.
• Suction-discharge manifolds can be connected on right or left.
• Silent operation.